Происхождение товара
Shanghai, China
Product Name
Flowmeter Electromagnetic Industrial processing FEP630 for chemical
Measuring value error
Standard 0.4 % of rate, option for 0.3% and 0.2 % of rate
Nominal diameter
DN 3 to 2000 (1/10 to 80 in.)
Process connection
DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129
Nominal pressure
PN 10 to 100, ASME CL 150, 300
Lining
Hard rubber, soft rubber, PTFE, PFA, ETFE, Linatex
Fluid temperature
Up to 180 °C (356 °F)
Communication
HART - PROFIBUS DP / Modbus /Ethernet
Process diagnostics
Empty pipe, partially filling, gas bubbles, electrode impedance